William Segars
William Segars
Associate Professor of Radiology, Duke University
Verified email at duke.edu
Title
Cited by
Cited by
Year
4D XCAT phantom for multimodality imaging research
WP Segars, G Sturgeon, S Mendonca, J Grimes, BMW Tsui
Medical physics 37 (9), 4902-4915, 2010
9652010
Dynamic imaging of allogeneic mesenchymal stem cells trafficking to myocardial infarction
DL Kraitchman, M Tatsumi, WD Gilson, T Ishimori, D Kedziorek, ...
Circulation 112 (10), 1451-1461, 2005
6712005
Development of a 4-D digital mouse phantom for molecular imaging research
WP Segars, BMW Tsui, EC Frey, GA Johnson, SS Berr
Molecular Imaging & Biology 6 (3), 149-159, 2004
4792004
Realistic CT simulation using the 4D XCAT phantom
WP Segars, M Mahesh, TJ Beck, EC Frey, BMW Tsui
Medical physics 35 (8), 3800-3808, 2008
4182008
Development and application of the new dynamic NURBS-based cardiac-torso (NCAT) phantom
WP Segars
The University of North Carolina at Chapel Hill, 2001
3372001
A realistic spline-based dynamic heart phantom
WP Segars, DS Lalush, BMW Tsui
IEEE Transactions on Nuclear Science 46 (3), 503-506, 1999
3271999
Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms
WP Segars, DS Lalush, BMW Tsui
IEEE Transactions on Nuclear Science 48 (1), 89-97, 2001
3022001
Development of a new dynamic NURBS-based cardiac-torso (NCAT) phantom
WP Segars
PhD ThesisThe, 2001
2902001
MCAT to XCAT: The evolution of 4-D computerized phantoms for imaging research
WP Segars, BMW Tsui
Proceedings of the IEEE 97 (12), 1954-1968, 2009
2012009
Four‐dimensional magnetic resonance imaging (4D‐MRI) using image‐based respiratory surrogate: a feasibility study
J Cai, Z Chang, Z Wang, W Paul Segars, FF Yin
Medical physics 38 (12), 6384-6394, 2011
1982011
Study of the efficacy of respiratory gating in myocardial SPECT using the new 4-D NCAT phantom
WP Segars, BMW Tsui
IEEE Transactions on Nuclear Science 49 (3), 675-679, 2002
1832002
Patient‐specific radiation dose and cancer risk estimation in CT: Part II. Application to patients
X Li, E Samei, WP Segars, GM Sturgeon, JG Colsher, G Toncheva, ...
Medical physics 38 (1), 408-419, 2011
1672011
Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization
WP Segars, J Bond, J Frush, S Hon, C Eckersley, CH Williams, J Feng, ...
Medical physics 40 (4), 043701, 2013
1472013
Accurate event-driven motion compensation in high-resolution PET incorporating scattered and random events
A Rahmim, K Dinelle, JC Cheng, MA Shilov, WP Segars, SC Lidstone, ...
IEEE transactions on medical imaging 27 (8), 1018-1033, 2008
1402008
Patient‐specific radiation dose and cancer risk estimation in CT: part I. Development and validation of a Monte Carlo program
X Li, E Samei, WP Segars, GM Sturgeon, JG Colsher, G Toncheva, ...
Medical physics 38 (1), 397-407, 2011
1372011
A Monte Carlo and physical phantom evaluation of quantitative In-111 SPECT
B He, Y Du, X Song, WP Segars, EC Frey
Physics in Medicine & Biology 50 (17), 4169, 2005
1332005
Methodology for generating a 3D computerized breast phantom from empirical data
CM Li, WP Segars, GD Tourassi, JM Boone, JT Dobbins III
Medical physics 36 (7), 3122-3131, 2009
1292009
Patient-specific radiation dose and cancer risk for pediatric chest CT
X Li, E Samei, WP Segars, GM Sturgeon, JG Colsher, DP Frush
Radiology 259 (3), 862-874, 2011
1142011
RADAR realistic animal model series for dose assessment
MA Keenan, MG Stabin, WP Segars, MJ Fernald
Journal of Nuclear Medicine 51 (3), 471-476, 2010
1112010
MRXCAT: Realistic numerical phantoms for cardiovascular magnetic resonance
L Wissmann, C Santelli, WP Segars, S Kozerke
Journal of Cardiovascular Magnetic Resonance 16 (1), 1-11, 2014
1042014
The system can't perform the operation now. Try again later.
Articles 1–20