Ehsan Samei
Ehsan Samei
Professor of Radiology, Medical Physics, Biomedical Engineering, Physics, and Electrical and Computer Engineering
Verified email at duke.edu
Title
Cited by
Cited by
Year
A method for measuring the presampled MTF of digital radiographic systems using an edge test device
E Samei, MJ Flynn, DA Reimann
Medical physics 25 (1), 102-113, 1998
8341998
Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm …
D Marin, RC Nelson, ST Schindera, S Richard, RS Youngblood, ...
Radiology 254 (1), 145-153, 2010
6472010
An experimental comparison of detector performance for direct and indirect digital radiography systems
E Samei, MJ Flynn
Medical physics 30 (4), 608-622, 2003
3582003
Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report
E Samei, A Badano, D Chakraborty, K Compton, C Cornelius, K Corrigan, ...
Medical physics 32 (4), 1205-1225, 2005
3472005
Towards task‐based assessment of CT performance: system and object MTF across different reconstruction algorithms
S Richard, DB Husarik, G Yadava, SN Murphy, E Samei
Medical physics 39 (7Part1), 4115-4122, 2012
2992012
Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT
CH McCollough, GH Chen, W Kalender, S Leng, E Samei, K Taguchi, ...
Radiology 264 (2), 567-580, 2012
2882012
Hypervascular Liver Tumors: Low Tube Voltage, High Tube Current Multidetector CT during Late Hepatic Arterial Phase for Detection—Initial Clinical Experience1
D Marin, RC Nelson, E Samei, EK Paulson, LM Ho, DT Boll, DM DeLong, ...
Radiology 251 (3), 771-779, 2009
2662009
Detection of subtle lung nodules: relative influence of quantum and anatomic noise on chest radiographs
E Samei, MJ Flynn, WR Eyler
Radiology 213 (3), 727-734, 1999
2571999
Intercomparison of methods for image quality characterization. II. Noise power spectrum a
JT Dobbins III, E Samei, NT Ranger, Y Chen
Medical physics 33 (5), 1466-1475, 2006
2402006
Hypervascular Liver Tumors: Low Tube Voltage, High Tube Current Multi–Detector Row CT for Enhanced Detection—Phantom Study1
ST Schindera, RC Nelson, S Mukundan Jr, EK Paulson, TA Jaffe, ...
Radiology 246 (1), 125-132, 2008
2262008
Intercomparison of methods for image quality characterization. i. modulation transfer function a
E Samei, NT Ranger, JT Dobbins III, Y Chen
Medical physics 33 (5), 1454-1465, 2006
2162006
Recent Advances in Chest Radiography1
HP McAdams, E Samei, J Dobbins III, GD Tourassi, CE Ravin
Radiology 241 (3), 663-683, 2006
2072006
An experimental comparison of detector performance for computed radiography systems
E Samei, MJ Flynn
Medical physics 29 (4), 447-459, 2002
1842002
Patient‐specific radiation dose and cancer risk estimation in CT: Part II. Application to patients
X Li, E Samei, WP Segars, GM Sturgeon, JG Colsher, G Toncheva, ...
Medical physics 38 (1), 408-419, 2011
1702011
Experimental comparison of noise and resolution for and storage phosphor radiography systems
MJ Flynn, E Samei
Medical physics 26 (8), 1612-1623, 1999
1691999
Detection of pancreatic tumors, image quality, and radiation dose during the pancreatic parenchymal phase: effect of a low-tube-voltage, high-tube-current CT technique …
D Marin, RC Nelson, H Barnhart, ST Schindera, LM Ho, TA Jaffe, ...
Radiology 256 (2), 450-459, 2010
1622010
A framework for optimising the radiographic technique in digital X-ray imaging
E Samei, JT Dobbins III, JY Lo, MP Tornai
Radiation Protection Dosimetry 114 (1-3), 220-229, 2005
1612005
An exposure indicator for digital radiography: AAPM Task Group 116 (executive summary)
SJ Shepard, J Wang, M Flynn, E Gingold, L Goldman, K Krugh, DL Leong, ...
Medical physics 36 (7), 2898-2914, 2009
1532009
Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization
WP Segars, J Bond, J Frush, S Hon, C Eckersley, CH Williams, J Feng, ...
Medical physics 40 (4), 043701, 2013
1502013
Patient‐specific radiation dose and cancer risk estimation in CT: part I. Development and validation of a Monte Carlo program
X Li, E Samei, WP Segars, GM Sturgeon, JG Colsher, G Toncheva, ...
Medical physics 38 (1), 397-407, 2011
1392011
The system can't perform the operation now. Try again later.
Articles 1–20