David Dance
David Dance
NCCPM, Royal Surrey County Hospital, Guildford
Verified email at nhs.net
Title
Cited by
Cited by
Year
The mammographic image analysis society digital mammogram database
P SUCKLING J
Digital Mammo, 375-386, 1994
16301994
Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol
DR Dance, CL Skinner, KC Young, JR Beckett, CJ Kotre
Physics in medicine & biology 45 (11), 3225, 2000
7542000
Monte-Carlo calculation of conversion factors for the estimation of mean glandular breast dose
DR Dance
Physics in Medicine & Biology 35 (9), 1211, 1990
5831990
European guidelines for quality assurance in mammography screening
N Perry, N Perry, M Broeders, J Schouten, C de Wolf, S Törnberg
Office for official publications of the European Communities, 2001
278*2001
Further factors for the estimation of mean glandular dose using the United Kingdom, European and IAEA breast dosimetry protocols
DR Dance, KC Young, RE Van Engen
Physics in Medicine & Biology 54 (14), 4361, 2009
2682009
Automatic computer detection of clustered calcifications in digital mammograms
DH Davies, DR Dance
Physics in Medicine & Biology 35 (8), 1111, 1990
2621990
Diagnostic radiology physics a handbook for teachers and students
DR Dance
inteRnational atoMic eneRgy agency, 2019
2132019
Influence of anode/filter material and tube potential on contrast, signal-to-noise ratio and average absorbed dose in mammography: a Monte Carlo study.
DR Dance, AK Thilander, M Sandborg, CL Skinner, IA Castellano, ...
The British journal of radiology 73 (874), 1056-1067, 2000
2042000
Estimation of mean glandular dose for breast tomosynthesis: factors for use with the UK, European and IAEA breast dosimetry protocols
DR Dance, KC Young, RE Van Engen
Physics in Medicine & Biology 56 (2), 453, 2010
1862010
The total cross sections for pion-proton scattering between 70 MeV and 290 MeV
AA Carter, JR Williams, DV Bugg, PJ Bussey, DR Dance
Nuclear Physics B 26 (3), 445-460, 1971
1771971
πp elastic scattering from 88 to 292 MeV
PJ Bussey, JR Carter, DR Dance, DV Bugg, AA Carter, AM Smith
Nuclear Physics B 58 (2), 363-377, 1973
1651973
X-ray refraction effects: application to the imaging of biological tissues
RA Lewis, CJ Hall, AP Hufton, S Evans, RH Menk, F Arfelli, L Rigon, ...
The British journal of radiology 76 (905), 301-308, 2003
1522003
The computation of scatter in mammography by Monte Carlo methods
DR Dance, GJ Day
Physics in Medicine & Biology 29 (3), 237, 1984
1521984
Measurement of small-angle photon scattering for some breast tissues and tissue substitute materials
SH Evans, DA Bradley, DR Dance, JE Bateman, CH Jones
Physics in Medicine & Biology 36 (1), 7, 1991
1481991
Breast dosimetry
DR Dance, CL Skinner, GA Carlsson
Applied Radiation and isotopes 50 (1), 185-203, 1999
1401999
Experimental investigation of the dose and image quality characteristics of a digital mammography imaging system
W Huda, AM Sajewicz, KM Ogden, DR Dance
Medical physics 30 (3), 442-448, 2003
1102003
Breast cancer diagnosis using scattered X-rays
RA Lewis, KD Rogers, CJ Hall, E Towns-Andrews, S Slawson, A Evans, ...
Journal of synchrotron radiation 7 (5), 348-352, 2000
1062000
Calculation of dose and contrast for two mammographic grids
DR Dance, J Persliden, GA Carlsson
Physics in Medicine & Biology 37 (1), 235, 1992
1041992
Breast dosimetry using high-resolution voxel phantoms
DR Dance, RA Hunt, PR Bakic, ADA Maidment, M Sandborg, G Ullman, ...
Radiation protection dosimetry 114 (1-3), 359-363, 2005
962005
Monte Carlo modelling of a‐Si EPID response: the effect of spectral variations with field size and position
L Parent, J Seco, PM Evans, A Fielding, DR Dance
Medical physics 33 (12), 4527-4540, 2006
892006
The system can't perform the operation now. Try again later.
Articles 1–20