Follow
Yoichi Watanabe, Ph.D.
Yoichi Watanabe, Ph.D.
Professor of Medical Physics, University of Minnesota
Verified email at umn.edu - Homepage
Title
Cited by
Cited by
Year
A validation study of a new prognostic index for patients with brain metastases: the Graded Prognostic Assessment
CM Sperduto, Y Watanabe, J Mullan, T Hood, G Dyste, C Watts, ...
Journal of neurosurgery 109 (Supplement), 87-89, 2008
1522008
Derivation of linear attenuation coefficients from CT numbers for low-energy photons
Y Watanabe
Physics in Medicine & Biology 44 (9), 2201, 1999
1051999
A mathematical model of tumor growth and its response to single irradiation
Y Watanabe, EL Dahlman, KZ Leder, SK Hui
Theoretical Biology and Medical Modelling 13, 1-20, 2016
1032016
Three-dimensional radiation dosimetry using polymer gel and solid radiochromic polymer: From basics to clinical applications
Y Watanabe, L Warmington, N Gopishankar
World journal of radiology 9 (3), 112, 2017
852017
Image distortion in MRI‐based polymer gel dosimetry of gamma knife stereotactic radiosurgery systems
Y Watanabe, GM Perera, RB Mooij
Medical Physics 29 (5), 797-802, 2002
612002
3D evaluation of 3DVH program using BANG3 polymer gel dosimeter
Y Watanabe, Y Nakaguchi
Medical Physics 40 (8), 082101, 2013
432013
Heterogeneity phantoms for visualization of 3D dose distributions by MRI‐based polymer gel dosimetry
Y Watanabe, R Mooij, G Mark Perera, MJ Maryanski
Medical Physics 31 (5), 975-984, 2004
402004
Evaluation of dose delivery accuracy of Gamma Knife by polymer gel dosimetry
Y Watanabe, T Akimitsu, Y Hirokawa, RB Mooij, GM Perera
Journal of Applied Clinical Medical Physics 6 (3), 133-142, 2005
382005
Geometrical accuracy of a 3-tesla magnetic resonance imaging unit in Gamma Knife surgery
Y Watanabe, CK Lee, BJ Gerbi
Journal of neurosurgery 105 (Supplement), 190-193, 2006
352006
Large expert-curated database for benchmarking document similarity detection in biomedical literature search
P Brown, AC Tan, MA El-Esawi, T Liehr, O Blanck, DP Gladue, ...
Database 2019, 2019
342019
Point dose calculations using an analytical pencil beam kernel for IMRT plan checking
Y Watanabe
Physics in Medicine & Biology 46 (4), 1031, 2001
332001
The local enhancement of radiation dose from photons of MeV energies obtained by introducing materials of high atomic number into the treatment region
A Alkhatib, Y Watanabe, JH Broadhurst
Medical physics 36 (8), 3543-3548, 2009
322009
Predicting the local response of metastatic brain tumor to gamma knife radiosurgery by radiomics with a machine learning method
D Kawahara, X Tang, CK Lee, Y Nagata, Y Watanabe
Frontiers in oncology 10, 569461, 2021
282021
Evaluation of triple channel correction acquisition method for radiochromic film dosimetry
N Hayashi, Y Watanabe, R Malmin, H Kato
Journal of radiation research 53 (6), 930-935, 2012
282012
Optimal radiotherapy dose schedules under parametric uncertainty
H Badri, Y Watanabe, K Leder
Physics in Medicine & Biology 61 (1), 338, 2015
272015
Three‐dimensional dosimetry of TomoTherapy by MRI‐based polymer gel technique
Y Watanabe, N Gopishankar
Journal of Applied Clinical Medical Physics 12 (1), 14-27, 2011
262011
A variable echo‐number method for estimating in MRI‐based polymer gel dosimetry
Y Watanabe, H Kubo
Medical physics 38 (2), 975-982, 2011
262011
Evaluation of a new self-developing instant film for imaging and dosimetry
Y Watanabe, GN Patel, P Patel
Radiation protection dosimetry 120 (1-4), 121-124, 2006
252006
A system for nonradiographic source localization and real‐time planning of intraoperative high dose rate brachytherapy
Y Watanabe, LL Anderson
Medical Physics 24 (12), 2014-2023, 1997
251997
One‐year analysis of Elekta CBCT image quality using NPS and MTF
S Nakahara, M Tachibana, Y Watanabe
Journal of applied clinical medical physics 17 (3), 211-222, 2016
242016
The system can't perform the operation now. Try again later.
Articles 1–20