Follow
Landon Wootton
Landon Wootton
Unknown affiliation
Verified email at uw.edu
Title
Cited by
Cited by
Year
Deep learning for patient‐specific quality assurance: Identifying errors in radiotherapy delivery by radiomic analysis of gamma images with convolutional neural networks
MJ Nyflot, P Thammasorn, LS Wootton, EC Ford, WA Chaovalitwongse
Medical physics 46 (2), 456-464, 2019
1192019
Temperature dependence of BCF plastic scintillation detectors
L Wootton, S Beddar
Physics in Medicine & Biology 58 (9), 2955, 2013
852013
MRI radiomic features are independently associated with overall survival in soft tissue sarcoma
MB Spraker, LS Wootton, DS Hippe, KC Ball, JC Peeken, MW Macomber, ...
Advances in radiation oncology 4 (2), 413-421, 2019
632019
Real-time in vivo rectal wall dosimetry using plastic scintillation detectors for patients with prostate cancer
L Wootton, R Kudchadker, A Lee, S Beddar
Physics in Medicine & Biology 59 (3), 647, 2014
552014
Error detection in intensity-modulated radiation therapy quality assurance using radiomic analysis of gamma distributions
LS Wootton, MJ Nyflot, WA Chaovalitwongse, E Ford
International Journal of Radiation Oncology* Biology* Physics 102 (1), 219-228, 2018
532018
A method to correct for temperature dependence and measure simultaneously dose and temperature using a plastic scintillation detector
F Therriault-Proulx, L Wootton, S Beddar
Physics in Medicine & Biology 60 (20), 7927, 2015
232015
Accuracy and stability of deep inspiration breath hold in gated breast radiotherapy–a comparison of two tracking and guidance systems
AM Kalet, N Cao, WP Smith, L Young, L Wootton, RD Stewart, LC Fang, ...
Physica Medica 60, 174-181, 2019
222019
Dosimetric characteristics of the University of Washington clinical neutron therapy system
GB Moffitt, RD Stewart, GA Sandison, JT Goorley, DC Argento, ...
Physics in Medicine & Biology 63 (10), 105008, 2018
202018
Reducing cardiac radiation dose from breast cancer radiation therapy with breath hold training and cognitive behavioral therapy
NA Mayr, KJ Borm, AM Kalet, LS Wootton, AL Chadderdon, SE Combs, ...
Topics in Magnetic Resonance Imaging 29 (3), 135-148, 2020
192020
Exradin W1 plastic scintillation detector for in vivo skin dosimetry in passive scattering proton therapy
F Alsanea, L Wootton, N Sahoo, R Kudchadker, U Mahmood, S Beddar
Physica Medica 47, 58-63, 2018
192018
Preliminary evaluation of the dosimetric accuracy of the in vivo plastic scintillation detector OARtrac system for prostate cancer treatments
SJ Klawikowski, C Zeringue, LS Wootton, GS Ibbott, S Beddar
Physics in Medicine & Biology 59 (9), N27, 2014
192014
Commissioning, clinical implementation, and performance of the Mobetron 2000 for intraoperative radiation therapy
LS Wootton, J Meyer, E Kim, M Phillips
Journal of Applied Clinical Medical Physics 18 (1), 230-242, 2017
162017
Characterizing a deformable registration algorithm for surface‐guided breast radiotherapy
J Meyer, W Smith, S Geneser, B Koger, AM Kalet, LA Young, N Cao, ...
Medical Physics 47 (2), 352-362, 2020
122020
Passively scattered proton beam entrance dosimetry with a plastic scintillation detector
L Wootton, C Holmes, N Sahoo, S Beddar
Physics in Medicine & Biology 60 (3), 1185, 2015
122015
Nearest neighbor-based strategy to optimize multi-view triplet network for classification of small-sample medical imaging data
P Thammasorn, WA Chaovalitwongse, DS Hippe, LS Wootton, EC Ford, ...
IEEE Transactions on Neural Networks and Learning Systems 34 (2), 586-600, 2021
112021
Effectiveness of a novel gas‐release endorectal balloon in the removal of rectal gas for prostate proton radiation therapy
LS Wootton, RJ Kudchadker, AS Beddar, AK Lee
Journal of applied clinical medical physics 13 (5), 190-197, 2012
92012
Regularizing the Deepsurv network using projection loss for medical risk assessment
P Thammasorn, SK Schaub, DS Hippe, MB Spraker, JC Peeken, ...
IEEE Access 10, 8005-8020, 2022
82022
Proton dose perturbations caused by high‐voltage leads from implanted cardioverter defibrillators
LS Wootton, JC Polf, S Peterson, J Wilkinson, MA Rozner, PA Balter, ...
Journal of applied clinical medical physics 13 (4), 13-22, 2012
72012
Dosimetric effects of bolus and lens shielding in treating ocular lymphomas with low-energy electrons
L Young, LS Wootton, AM Kalet, O Gopan, F Yang, S Day, M Banitt, ...
Medical Dosimetry 44 (1), 35-42, 2019
62019
4D computed tomography scans for conformal thoracic treatment planning: is a single scan sufficient to capture thoracic tumor motion?
YD Tseng, L Wootton, M Nyflot, S Apisarnthanarax, R Rengan, C Bloch, ...
Physics in Medicine & Biology 63 (2), 02NT03, 2018
62018
The system can't perform the operation now. Try again later.
Articles 1–20